Blower Door Testing with Infrared: For new construction we perform a simple Blower Door Test to ensure that the house is code compliant. While one can also perform this test only on an existing house, there is just one small issue – it only tells you how leaky it is, not where the leaks are. Granted you can use the back of the hand method, a
Marshall Insulation offers comprehensive home energy audits, including blower door tests, for Phoenix area homeowners. In addition to diagnosing inefficient air leakage, we can also help you correct problems by sealing and insulating the troublesome areas of your home, including the walls, attic, basement, crawl space and elsewhere.
Blower door test equipment consists of a large, powerful fan that is fitted into an exterior door in your home. Its adjustable panels allow our team to fit it tightly within the door frame. When turned on, the powerful fan will blow interior air outside and create negative air pressure within your home. To ensure the blower door can properly
So first, check the fireplace for ashes. One method I’ve found that keeps the ashes out of the house is to lay newspaper over the fireplace and then use a spray bottle filled with water to wet the newspaper. It works. 5. Make sure your helpers know where to seal the vents.
A blower door test is an experiment to measure air leakage from a home, with the goal of finding and fixing any weak points within its air barrier. The test is performed by a contractor or licensed energy auditor using special equipment to seal and pressurize (or depressurize) the home. A single door of the home is fitted with a large
Video describing how to conduct a residential blower door and duct blaster test, including an efficient method for setting up the blower door equipment and how to set up the fan rings and the manometer. Video 4 of 9.
How Does a Blower Door Test Work? During a blower door test, a fan is mounted into the frame of an exterior door, creating a pressure difference that allows air leaks to be detected. The test can be conducted in either a depressurization or pressurization method, with an infrared camera used to identify air leakage points.
As an example, a home had a blower door test of 750 CFM and a calculated volume of 12,000 cubic feet. Using the formula, 750 CFM x 60 minutes / 12,000 cubic feet = 3.75 ACH50. This home would pass the blower door test in some areas of the country where the test result must be 5 ACH50 or less, but not in others where the requirement is 3 ACH50
The 2016 NYCECC also requires that buildings between 25,000 and 50,000 square feet and less than 75 feet in height perform a blower door test and certify that the air leakage is less than 0.4 cubic feet per minute of enclosed building area, per Section C402.5.1.3. Buildings requiring air leakage testing and containing multiple dwelling units The Blower Door test simulates the following: If a home has wind blowing against it at 20 miles per hour, the total volume of air within the house would exchange with outside air 7 times. The 20 mph wind is equivalent to 50 Pascals (Pa) pressure difference that we are simulating using the Blower Door Fan. All homes are tested at this 50 Pa
Calibrating AZC door actuators. Calibrate the door actuators after making any repairs to the AZC system. To calibrate the door actuators proceed as follows: 1. Turn the ignition on. 2. Set the AZC to automatic. 3. Turn the ignition off. 4. Remove the IOD fuse from the Power Distribution Center. Wait several seconds, and then install the IOD
Troubleshoot the indoor air handler or blower unit for A/C or heat pump or furnace system. How to inspect & repair the indoor components of air conditioners and heat pumps: the air conditioning system indoor air handler units, blower units, or AHU's, (also called fan coil units) including the air conditioner blower fan, the indoor cooling coil or "evaporator coil", air conditioning system
An air change is when a volume of air equal to the volume of the house exchanges with outside air. One ACH, then, means all the air in the house exchanges once per hour. With the Blower Door running and the house pressure at negative 50 Pascals, a typical existing home might leak at the rate of 15 air changes per hour, which is written 15 ACH50.

How Does the Blower Door Test Work? The blower door test uses a powerful fan mounted into the frame of an exterior door. The fan then pulls air out of the building or residence, reducing inside air pressure. The outside air, which is at a higher pressure, then flows in through unsealed cracks and openings. The test determines the air